Backup power for homes and businesses
+38 063 793 29 29Discuss your power requirements
BASTION / SERVICE

Generator and backup power service

Maintenance, diagnostics and repair for gas, diesel and petrol generators. Discuss the condition of your equipment and agree the work it needs.

We provide service in Odesa and Odesa Oblast, Kyiv and Kyiv Oblast.

Discuss by phone
GAS / DIESEL / PETROL

From scheduled maintenance to fault diagnosis

Start with your requirements. Tell us the model, operating hours and what has changed.

01

Scheduled maintenance

Oil, filters, spark plugs and other consumables according to the specific model’s maintenance schedule. System condition checks and preparation for further use.

02

Diagnostics

A generator that will not start, displays a fault, stalls or cannot support its load needs an assessment. Symptoms, operating conditions and service history help identify the cause.

03

Repairs

Work is agreed after diagnosis: engine, electrical system, starting, charging or controls. The repair scope and parts depend on the model and the identified fault.

04

Transfer switches and controls

Review of automatic starting, transfer to backup power and return to the grid. The generator, transfer switch and connected loads need to be assessed together.

05

Connection and commissioning

Discuss the backup power arrangement, transfer-switch compatibility and site readiness. Pre-start checks are agreed for the model and installation conditions.

06

Seasonal and storage preparation

Checks after extended storage and preparation for outages. Fuel, battery condition and the manual’s requirements matter when storing or returning equipment to use.

BASTION / CARE

What the assessment covers

The exact scope depends on the model, its condition and the task. These are the principal systems considered during service.

When is maintenance due?

Follow the manual for your exact model. Maintenance typically depends on both operating hours and elapsed time, whichever limit is reached first. Harsh conditions, extended operation or storage may call for additional checks. There is no single interval for every generator.

Engine and consumables
Condition of oil, filters, spark plugs and belts where fitted.
Fuel, cooling and ventilation
Accessible connections, signs of leaks, cooling and unobstructed heat dissipation.
Starting and battery
Battery, charging, starter and starting in the intended operating mode.
Electrical system and controls
Connections, readings, fault codes, voltage checks and control functions.
Load testing
Assessment with an agreed load and a record of findings.

Prepare the details for a useful first conversation

These details help us understand the task with fewer follow-up questions.

  1. Brand, model and serial number from the data plate.
  2. Operating hours and the date of the last service.
  3. Fault code and symptoms: when the problem occurs, how the generator starts and which loads are connected.
  4. Equipment location, fuel type and transfer-switch details.
  5. Prepare photographs of the data plate, controller display and installation for the follow-up conversation.

How a service enquiry works

01

Enquiry

Leave your contact details and describe the task.

02

Clarification

Agree the initial information and diagnostic approach.

03

Scope of work

Discuss the work, materials, cost and timing.

04

Outcome

Checks following the agreed work and operating recommendations.

Service questions

Can I enquire about another generator brand?

Include the brand and model. Service, diagnostics and parts availability are confirmed for the specific equipment.

How much does maintenance or repair cost?

Cost depends on the model, operating hours, condition, materials and work arrangement. Repairs require the fault to be understood first. The scope is agreed before work starts.

Can you attend the site?

We provide service in Odesa and Odesa Oblast, Kyiv and Kyiv Oblast. Include the town or city and site access details. Available work arrangements and site attendance are agreed for each enquiry.

What if the generator is under warranty?

Prepare purchase and commissioning documents, the serial number and service history. Warranty conditions and the manufacturer’s or seller’s claims process need to be checked before intervention.

Does a rarely used generator still need maintenance?

Yes. Follow calendar requirements as well as operating hours. Batteries, fluids, fuel and connections also require attention during storage.

Need generator service?

Describe a fault or plan maintenance. Start with your generator’s model and condition.

BASTION LTD

Оберіть мову

Выберите язык · Choose your language

Generator power calculator

What needs to keep running during an outage? Add appliances to estimate your load and headroom.

Example values are editable. Use electrical input power from the appliance nameplate, not heat output or mechanical output.

How we calculate

One-at-a-time starting: total running power + the largest additional starting load of one appliance. All-at-once starting: the sum of all starting loads. Headroom is added to the resulting peak.

Generac: sizing guide ↗